PEX Tubing Loop Length & Coil Count Calculator

Calculate exact PEX-A/B oxygen-barrier tubing length, coil count, and loop spacing. Automatic loop splitting at 300 ft (1/2in) or 200 ft (3/8in) max, with 10% waste factor and transit tails.

Quick Room Presets

Start from a common project size, then customize.

System-Wide Settings

Apply to all rooms/zones.

Rooms / Zones (1)

1

Cabinets, vanities, showers, islands — don't run PEX under these.

Net Heated Area100 sq ft

Current: 28 BTU/sq ft

This room:1 loop209 ft/loop210 ft PEX

Hydronic System Summary

Net Heated Area
100sq ft
Total Heat Load
2,800BTU/hr
Total PEX Tubing
210ft
Required Flow
0.4GPM
Loops
1
Per Loop
209ft
Manifold Ports
1
PEX Rolls
1×300ft
Balanced Loops — all loops are within 10% length variance and under the 300 ft max per loop. No hydraulic short-circuiting risk.

Estimate only: These results are planning estimates, not a stamped engineering design or a Manual J heat-loss calculation. Have a licensed HVAC or plumbing contractor confirm loads and loop layout, and get permits where your local code official requires them.

Assumptions, units & code references
  • Heat loss uses a typical BTU/hr per sq ft value for the insulation level you choose.
  • Flow is based on that load and the design temperature drop (15 °F by default).
  • Loop lengths include the run to the manifold and a 10% allowance, and each loop stays under the maximum length for the PEX size.

Units: Square feet (sq ft), BTU per hour (BTU/hr), feet of tubing (ft), gallons per minute (GPM), degrees Fahrenheit (°F).

Code references: Hydronic piping is covered by your locally adopted mechanical and plumbing codes, not the National Electrical Code. Circulators, zone actuators and thermostats still need wiring that meets the NEC edition your area enforces.

Equipment Checklist

Buyer-ready shopping list with exact quantities. Click any item to check current pricing on Amazon.

Disclosure: HeatedFloorCalc earns a commission if you buy through the links below, at no extra cost to you. As an Amazon Associate we earn from qualifying purchases. Products are matched to your calculated specs; check the manufacturer’s data before buying.

1
1/2" Oxygen-Barrier PEX Tubing
1 × 300 ft coil (210 ft total incl. 10% waste). Zero underground splices.
Why you need this: Covers your total loop length with the calculated roll size.
PEX Tubing
2
1-Port Stainless Steel Hydronic Manifold
1-port manifold with flow meters and balancing valves to match 1 loop.
Why you need this: One port per calculated loop.
Manifold
3
Thermostatic Mixing Valve
Temps the supply water for radiant loops. Sized for 0.4 GPM flow rate.
Why you need this: Keeps supply water at a safe floor temperature.
Mixing Valve
4
Circulator Pump
Matched to 0.4 GPM total system flow. Choose a variable-speed ECM pump for zone efficiency.
Why you need this: Moves the calculated GPM through the loops.
Circulator Pump
5
PEX Foamboard Staples / Clips
Secures PEX to insulation foamboard at 8" spacing during slab/pour installation.
Why you need this: Holds tubing at your calculated spacing.
Fasteners
6
PEX Crimping / Expansion Tool Kit
Complete tool kit for 1/2" PEX connections (crimp or expansion per your fitting type).
Why you need this: Makes the manifold and loop connections.
Tools
7
Programmable Hydronic Thermostat + Zone Actuators
1 zone thermostat with matching actuator for manifold ports.
Why you need this: Zone control for each room.
Thermostat

What this PEX tubing calculator does

This tool sizes oxygen-barrier PEX for a US hydronic radiant floor. Enter each room’s gross area, obstacle area, tube spacing, PEX size, and the walk-off distance to the manifold. The calculator returns field footage, loop count, per-loop length, total PEX including 10% waste, suggested coil counts, heat load, GPM, and manifold ports.

The formula

Net area = gross area − obstacles. Field footage = net area × ft per sq ft, where 6, 8, 9, and 12 inch spacing use 2.0, 1.5, 1.33, and 1.0 ft/sq ft. Loops are the smallest whole n such that (field / n + 2 × manifold distance) × 1.1 stays at or under 300 ft for 1/2 inch PEX or 200 ft for 3/8 inch PEX. Per-loop length is rounded to the nearest foot, then multiplied by the loop count. Loops are calculated per room and then summed.

Worked example

For 1,000 sq ft net, 8 inch spacing, a 50 ft manifold distance, and 1/2 inch PEX, field footage is 1,500 ft. The calculator uses 9 loops at 293 ft each and reports 2,640 ft of total PEX, typically as 3 × 1,000 ft coils. Buying only the 1,500 ft field length leaves out almost 1,140 ft of transit and waste.

If you are deciding how tight to lay the tube, see PEX spacing for radiant floors. For the length cap itself, read radiant floor loop length. A full walkthrough of the order quantity is in how many feet of PEX you need.

As an Amazon Associate I earn from qualifying purchases.

Frequently asked questions

How much PEX does 1,000 sq ft at 8 inch spacing need?
With a 50 ft manifold run and 1/2 inch PEX, the calculator returns 2,640 ft of total PEX on 9 loops at 293 ft, not just the 1,500 ft field footage.
Do I add transit once for the whole system?
No. Transit is 2 × the manifold distance on every loop. Nine loops with a 50 ft run carry 900 ft of supply and return before the 10% waste factor.
What is the maximum loop length?
This site uses 300 ft for 1/2 inch PEX and 200 ft for 3/8 inch PEX, including transit and waste. Check the tubing manufacturer for the limit that applies to your product.
Why are rooms calculated separately?
Different rooms can have different areas, spacing, and manifold distances. Counting loops per room, then summing, keeps each circuit under the length cap and makes the manifold easier to balance.

Related tools and guides